Low-battery policy on the board (task 6.6; board-read)

2026-10-14, landscape image s53ywx90…, second board in the keyboard case. Evidence class: board-read (journal and sysfs samples). No camera frame: the bench webcam cannot see the panel, and the two shade captures the script tried to take failed (grim as user shell could not write into the root-owned log directory).

Method

policy-test.sh ran on the board as a transient unit (systemd-run). It:

  1. wrote /run/k230-battery-policy.json = {"warn": 100, "urgent": 99, "shutdown": 98}, the override the service reads every loop;
  2. set the charger’s Hi-Z (echo 0 > …/bq25890-charger-0/online): USB-C stays plugged, the input is disconnected and the battery carries the system, a real discharge of about 400 mA;
  3. once “Battery critically low” appeared, set online back to 1 (the cable cancel, by software), then cut it again and let the countdown run out;
  4. sampled charger and gauge every 10 s into samples-2026-10-14.log.

A first start at 00:37:15 CDT had no PATH under systemd-run and was stopped within 30 s; its Hi-Z had already produced the first “Battery low” line. The charger was restored (which re-arms the warnings) and the run restarted at 00:37:59.

Result (journal-2026-10-14.log, times CDT)

TimeGaugePolicy
00:38:07100 %, Discharging, ~-400 mABattery low: 100% remaining.
00:42:3799 %Battery very low: 99% remaining.
00:47:0798 %, two readingsBattery critically low: Shutting down in 60 seconds.
00:47:21charger online 1, Charging—
00:47:22Charging: Shutdown cancelled.
00:47:52charger online 0 again—
00:48:5298 %, two readingsBattery critically low: Shutting down in 60 seconds.
00:49:52logind: poweroff requested from client … (unit k230-battery-policy.service)
00:49:58Reached target System Power Off; systemd-shutdown: sync, SIGTERM

The notifications, the countdown, the cancel and the orderly shutdown all happened as specified.

The board did not power off

After the last journal line the panel stayed lit and the board stopped responding; the operator pressed the reset button. This kernel has no power-off path: OpenSBI here offers no SRST extension (dmesg lists TIME, IPI, RFENCE, DBCN, HSM only), and the K230 PMU driver was ported without LILYGO’s system-off callback (power-key task 1.2). So systemctl poweroff ends in a halt with the board still powered, and on battery that keeps draining the cell. Until a power-off handler exists, the policy’s shutdown protects the filesystem but not the battery.

Also found: the charger’s Hi-Z survived the halt and the reset (REG00 0xff, online 0 after boot) because nothing resets the BQ25896. It was cleared by hand. The test’s last-moment “reconnect the charger” hook was put in /run/systemd/system-shutdown/, which systemd-shutdown does not read, so it never ran.

Rerun on the power-off kernel (2026-10-14 02:18–02:31 CDT)

System 9m683dbp…, with the PMU power-off handler restored (../../power-key/power-off/README.md). Same method and override as above. Two fixes to the test itself: the charger is reconnected by the transient unit’s ExecStopPost (it ran when shutdown stopped the unit), and the capture directory is world-writable so grim as shell can write. policy-test.sh here is the script as run.

journal-poweroff-2026-10-14.log, samples-poweroff-2026-10-14.log:

Time (CDT)Event
02:18:12charger Hi-Z, gauge -413 mA, 100 %
02:18:33Battery low: 100% remaining.
02:22:33Battery very low: 99% remaining.
02:27:03Battery critically low: Shutting down in 60 seconds.
02:27:24–28charger back on; Charging: Shutdown cancelled.
02:27:55charger Hi-Z again
02:28:28Battery critically low: Shutting down in 60 seconds.
02:29:28logind: poweroff requested … (unit k230-battery-policy.service)
02:29:34–35Finished System Power Off; systemd-shutdown: sync, SIGTERM
02:30:14next boot, after the operator held the power key

Operator: “it went fully dark. i powered it back on”. After boot the charger read online 1, REG00 0x7f, Charging, and the override file was gone: the cleanup ran before power was cut.

shade-countdown-grim.png is a native capture of the shade three seconds into the first countdown: one System notification, “Battery critically low / Shutting down in 60 seconds. Connect a charger to cancel.”, battery line 98 %. The script’s second capture, 3 s after “Shutdown cancelled”, was byte-identical: an open shade read notification history only when it opened, so the tag replacement never reached it. Reproduced afterwards with k230-notifications emit (center history held “Charging”, shade still showed the countdown 13 s later) and fixed separately (shade adopts the banner poll’s history while open).

Evidence classes: board-read (journal, sysfs, native capture) and operator report of the power cut. No camera frame.