Landscape DRM connector polling and mutex waits
This is a diagnostic on the unchanged landscape board, following the kernel
sleep-stack evidence in ../landscape-drm-wait/README.md. It does not change
hotplug behavior, the installed image, output geometry, or shell defaults.
Method and qualification
tools/landscape-drm-holder.py reuses the existing 24-drag direct-IPC workload
(35 move events over nominal 0.7s, 1.6s rest, 864 complete input/present joins).
The pair uses the same existing DEBUG Sway process, one idle Foot and pinned
color follower, source 221bbcf34a276a939356e5a6af9bfb124af9896a, and installed/persistent
system /nix/store/j30yag05ic9k68n9dzbzindgf4ardp08-nixos-system-nixos-26.11.20260919.20b1ddd.
HDMI remains 1280x800, normal transform, scale 1, 59.91Hz. No camera or real-glass
input was used; this does not complete any deferred portrait evidence gate.
An exclusive tracefs instance records target-PID scheduler and raw syscall
scalars plus seven selected kernel function entries. The public function
stream contains only timestamps, PIDs, CPU, and allowlisted function/caller
symbols. Other caller symbols become [other]; raw pointers, names and
arguments remain in private originals and are not committed. Each stream is
hashed. Monotonic markers bracket time.monotonic_ns; the report requires
zero overrun/commit-overrun/drops and exact numeric+function ring entries.
An independent 600s cleanup timer precedes mutation. Cleanup verifies owned
inode, event filters, tracer and function filters; global controls are hashed
and must remain unchanged.
The pinned kernel source excerpts and file hashes are in
preflight/kernel-grounding.json. drm_helper_probe_detect_ctx acquires its
device’s connection_mutex, calls detect_connector_status on success, then
calls drm_modeset_drop_locks. The measured interval from detect entry to
drop-lock entry is therefore a conservative held-lock interval, not an
exact acquisition-to-release duration. Qualification requires a complete
poll/probe/detect/LT9611/drop sequence on the same worker PID with matching
callers. Backoff or ambiguous/incomplete probe sequences are rejected. The
small probe helper can be inlined: an observed direct output_poll_execute
caller is accepted, or a separately observed helper caller chain is required.
A poll may inspect multiple connectors; each completed probe is qualified
separately.
Smoke and rejected attempt
Source 6c15edd550c69121681aff085ec1c9d05c432bcc completed its first 25s idle
capture with strict exports and successful cleanup, but its interval checker
rejected the actual compiler-inlined helper path. The driver exited 2;
that rejection and unchanged records remain in board/rejected-smoke-a/.
It is not a qualified smoke or an exit-0 run.
Source 9afa87c925b823c44340c901b795a89a106484e6, tool SHA256
49ef1e5b7de367527a1ab8380a4b8fb9413547dfac9e76e684eb829ddfc19c98, adds the
inlining/multiple-probe regression fixture. All eight host test methods pass;
these are tooling tests only. A fresh board smoke in a new directory qualified
at 2026-10-20T16:05:42Z: 39 numeric and 124 function records, three complete
poll cycles, no loss or rejected intervals, all clock/count/cleanup checks
passed. Each cycle contained a fast ~0.4ms probe followed by a slow probe
holding the connection mutex for at least 173.679–176.931ms. This idle
measurement does not establish that a particular shell input was blocked.
Paired board result
The original board driver exited 0 (board/trial-a/command.json and
driver.log). It performed exactly one untraced workload, one instrumented
workload, and the single permitted instrumented retry because the first
instrumented workload had no >100ms input. No additional trial was run.
Each workload has 864 complete input/present joins.
| Run | Wall p95 / p99 / max (ms) | Inputs >100ms | Frame CPU p95 / max (ms) |
|---|---|---|---|
| Untraced | 27.331 / 45.781 / 208.050 | 1 | 4.884 / 5.456 |
| Traced | 25.920 / 46.181 / 47.399 | 0 | 5.030 / 5.971 |
| Traced retry | 28.328 / 47.052 / 201.241 | 5 | 5.056 / 5.924 |
Wall p95 differed from untraced by -1.411/+0.997ms and frame CPU p95 by +0.146/+0.173ms (~3.0/3.5%). These include phase variation and tracing; they are not an isolated overhead calibration or an improvement claim. The first traced run still recorded six slow poll holds (177.217–181.465ms) but no >100ms DRM call. The retry recorded six slow holds (171.749–188.606ms) and six >100ms DRM calls; five overlapped late input samples and one occurred outside late input samples. Poll starts were approximately 10.240s apart.
The retry’s five late samples are:
| Input / frame | Input→present (ms) | Frame CPU (ms) | Long DRM ioctl / wall (ms) | Main-thread sleep (ms) | Slow poll held interval (ms) | Drop entry→wakeup (µs) |
|---|---|---|---|---|---|---|
| 54 / 13015 | 184.382 | 5.303 | ATOMIC / 171.662 | S / 171.310 | 179.229 | 30 |
| 194 / 13260 | 201.241 | 4.772 | OBJ_GETPROPERTIES / 180.604 | D / 180.547 | 187.659 | 31 |
| 333 / 13500 | 185.854 | 5.366 | ATOMIC / 168.060 | S / 167.691 | 171.749 | 30 |
| 480 / 13764 | 193.735 | 4.761 | OBJ_GETPROPERTIES / 165.752 | D / 165.691 | 183.873 | 29 |
| 621 / 14017 | 184.564 | 4.800 | OBJ_GETPROPERTIES / 170.749 | D / 170.681 | 182.381 | 31 |
The two atomic waits occur after frame submission; the three property-query waits occur before submission. Wake→run was 17–21µs for these main waits. Worker PIDs 101141/101254 execute the complete source-qualified polling call chain. Their connector mutex is held throughout the measured detect→drop intervals. The shell’s DRM calls overlap those intervals, its sleeping thread wakes just after drop entry, and the previous unchanged-kernel diagnostic locates these call paths in modeset mutex acquisition. The polling worker is the source-grounded connector-mutex holder associated with these five stalls. This conclusion uses the observed critical section and wakeup, not the scheduler’s next-task PID.
board/final-check.json maps the shell’s DRM descriptors 10/11/12 to card0,
which owns disabled/disconnected DSI-1 and enabled/connected HDMI-A-1. The
atomic connector-state path and polling detector take that device’s
connection mutex; the all-lock property-query path takes it first. Symbol
tracing does not export mutex addresses or a connector identifier, so the
per-probe connector identity is not independently recorded.
The trace qualifies 12 held intervals per instrumented run (two probes for
each of six poll cycles), with zero rejected probe intervals. Exact ring
counts are 371,915 numeric + 4,911 function = 376,826 entries, and
370,565 + 4,854 = 375,419 entries for the retry. All overrun, commit-overrun
and dropped-event counters are zero. Clock markers cover all input/present
samples. The strict report and original capture/export hashes are in
board/report.json and the run trace.json files.
Capture/controller source remains 9afa87c925b823c44340c901b795a89a106484e6
(SHA49ef1e5b… above); the board copy was not overwritten after qualification.
Host reporting source ad032fa4f299dad9763acd6f516f88fd26a2f4d9, SHA256
6c12fc6b5179e1ff35415076f101687e4878bb846761c11df162f74a2917346f,
adds all long DRM calls including input-idle intervals, checks paired
capture/smoke/exporter identities, and records report_tool_sha256 separately.
It does not change capture code, timestamps, counts, records or hashes.
Private raw files remain outside Git, byte/hash-verified against their
original metadata before public curation. Only sanitized deterministic gzip
streams are committed, each with its own binary inventory entry.
Normal state
At 2026-10-20T16:21:34Z, final hardware checks confirmed all four owned trace instances/function tracers removed, all cleanup timers inactive, six global control hashes unchanged, Home/benchmark-stop successful, both shell services active, the original idle Foot/color follower, zero virtual test devices, and unchanged PID77507, executable/config, source221/j30 image, DEBUG settings and landscape output. No reboot, flash, shell restart, persistent override or default change occurred. The private copy finished and hashes passed before releasing the board reservation.
Limits
A source-grounded held-lock interval and its overlap with a syscall require interpretation; no mutex address is exported, and the scheduler’s next PID is not used to infer ownership. The prior diagnostic captured actual kernel sleep stacks in modeset mutex acquisition; this probe adds polling critical sections without capturing new sleep stacks. All wall durations include instrumentation and scheduling. Paired differences are observed, not an isolated overhead calibration.
The full detect path includes bridge and HDMI helper work. Source shows that HDMI hotplug update may reread EDID within detection. This probe does not measure the duration of the individual status-register read, EDID read, or I2C transaction. No hotplug fix, polling-disable comparison, optical smoothness, native input, portrait result, reboot or flash is claimed.
Publication
Evidence commit 7bde62b31f21dbb20f79516cca6b171cb76d72b2 passed
CI39457713772.
At 2026-10-20T16:32:42Z, the public workboard returned HTTP200 and its
data-revision exactly matched that commit. publication.json retains the
URL, timestamp and comparison. All six diagnostic tasks are complete;
there are no delta specs or accepted capability changes to sync. The
original portrait change remains separate with nine hardware/profile gates
open; this diagnostic does not complete them. No image deployment is
needed for these tooling/evidence changes. A performance fix and its
hotplug/native/optical regression proof remain future work.